How it works
cooling ≈ area × 20 BTU/sq ft × sun factor + 600 BTU per person over two (+4,000 for a kitchen)
heating ≈ area × 30–60 BTU/sq ft by climate
The sun factor lowers the estimate 10% for a heavily shaded room and raises it 10% for a very sunny one. These are the rules of thumb used for sizing room (window and portable) units. Whole-house systems should be sized with a proper load calculation (Manual J) that accounts for insulation, windows, ceiling height and local climate.
Estimated BTU by room size
| Room | Cooling (BTU/h) | Common AC size | Heating, warm climate | Heating, cool climate |
|---|---|---|---|---|
| 150 sq ft | 3,000 | 5,000 | 4,500 | 7,500 |
| 250 sq ft | 5,000 | 5,000 | 7,500 | 12,500 |
| 350 sq ft | 7,000 | 8,000 | 10,500 | 17,500 |
| 450 sq ft | 9,000 | 10,000 | 13,500 | 22,500 |
| 550 sq ft | 11,000 | 12,000 | 16,500 | 27,500 |
| 700 sq ft | 14,000 | 14,000 | 21,000 | 35,000 |
| 1000 sq ft | 20,000 | 24,000 | 30,000 | 50,000 |
| 1200 sq ft | 24,000 | 24,000 | 36,000 | 60,000 |
| 1500 sq ft | 30,000 | 30,000 | 45,000 | 75,000 |
| 2000 sq ft | 40,000 | 48,000 | 60,000 | 100,000 |
Rule-of-thumb estimate, not an engineering load calculation. An oversized AC short-cycles and removes less humidity; an undersized one runs constantly.
AC size by room area
- 100 sq ft
- 150 sq ft
- 200 sq ft
- 250 sq ft
- 300 sq ft
- 350 sq ft
- 400 sq ft
- 450 sq ft
- 500 sq ft
- 550 sq ft
- 600 sq ft
- 650 sq ft
- 700 sq ft
- 750 sq ft
- 800 sq ft
- 850 sq ft
- 900 sq ft
- 950 sq ft
- 1,000 sq ft
- 1,100 sq ft
- 1,200 sq ft
- 1,300 sq ft
- 1,400 sq ft
- 1,500 sq ft
- 1,600 sq ft
- 1,700 sq ft
- 1,800 sq ft
- 1,900 sq ft
- 2,000 sq ft
- 2,100 sq ft
- 2,200 sq ft
- 2,300 sq ft
- 2,400 sq ft
- 2,500 sq ft