96 in rise → 13 steps of 7.38 in
By maximum riser height
| Riser limit | Risers | Riser (in) | Treads | Run at 10 in (in) | Angle |
|---|---|---|---|---|---|
| 7 in max | 14 | 6.86 | 13 | 130 | 36.4° |
| 7.25 in max | 14 | 6.86 | 13 | 130 | 36.4° |
| 7.5 in max | 13 | 7.38 | 12 | 120 | 38.7° |
| 7.75 in max | 13 | 7.38 | 12 | 120 | 38.7° |
By tread depth (13 risers)
| Tread | Total run (in) | Run (ft) | Stringer (in) | Angle |
|---|---|---|---|---|
| 10 in tread | 120 | 10 | 153.7 | 38.7° |
| 10.5 in tread | 126 | 10.5 | 158.4 | 37.3° |
| 11 in tread | 132 | 11 | 163.2 | 36° |
Stringer stock: a 12.8 ft stringer is usually cut from a 14 ft 2×12. Treads are counted without nosing.
Other rises
Uses typical U.S. residential guidelines (7¾ in max riser, 10 in min tread). Confirm with your local code.