120 in rise → 16 steps of 7.5 in
By maximum riser height
| Riser limit | Risers | Riser (in) | Treads | Run at 10 in (in) | Angle |
|---|---|---|---|---|---|
| 7 in max | 18 | 6.67 | 17 | 170 | 35.2° |
| 7.25 in max | 17 | 7.06 | 16 | 160 | 36.9° |
| 7.5 in max | 16 | 7.5 | 15 | 150 | 38.7° |
| 7.75 in max | 16 | 7.5 | 15 | 150 | 38.7° |
By tread depth (16 risers)
| Tread | Total run (in) | Run (ft) | Stringer (in) | Angle |
|---|---|---|---|---|
| 10 in tread | 150 | 12.5 | 192.1 | 38.7° |
| 10.5 in tread | 157.5 | 13.13 | 198 | 37.3° |
| 11 in tread | 165 | 13.75 | 204 | 36° |
Stringer stock: a 16 ft stringer is usually cut from a 18 ft 2×12. Treads are counted without nosing.
Other rises
Uses typical U.S. residential guidelines (7¾ in max riser, 10 in min tread). Confirm with your local code.