138 in rise → 18 steps of 7.67 in
By maximum riser height
| Riser limit | Risers | Riser (in) | Treads | Run at 10 in (in) | Angle |
|---|---|---|---|---|---|
| 7 in max | 20 | 6.9 | 19 | 190 | 36° |
| 7.25 in max | 20 | 6.9 | 19 | 190 | 36° |
| 7.5 in max | 19 | 7.26 | 18 | 180 | 37.5° |
| 7.75 in max | 18 | 7.67 | 17 | 170 | 39.1° |
By tread depth (18 risers)
| Tread | Total run (in) | Run (ft) | Stringer (in) | Angle |
|---|---|---|---|---|
| 10 in tread | 170 | 14.17 | 219 | 39.1° |
| 10.5 in tread | 178.5 | 14.88 | 225.6 | 37.7° |
| 11 in tread | 187 | 15.58 | 232.4 | 36.4° |
Stringer stock: a 18.2 ft stringer is usually cut from a 20 ft 2×12. Treads are counted without nosing.
Other rises
Uses typical U.S. residential guidelines (7¾ in max riser, 10 in min tread). Confirm with your local code.